Safety management during valve maintenance

workshop08
workshop06

2nd.

HSE management system and measures

1. HSE Policy and Principles:
2. HSE management measures:

3rd.

Valve maintenance and troubleshooting

1. Daily maintenance
2. Common faults and solutions
No.Fault phenomenonCause of issueApproach
1Valve opening and closing failureThe packing is too tight and the gland is skewedAdjust the tightness of the stuffing box bolts and the gland pressure
Opening and closing parts fall offReplacement of valves
Bent valve stem, damaged valve stem threads, scale accumulationStraighten the valve stem, repair the valve stem threads and descale
The closing force of the gate valve is too large or the valve stem expands due to heatTap the valve body flange while turning the handwheel
The bracket bearing is loose and presses against the hand wheelRe-fix the bearing gland
Cold season freezingSteam properly heated valve
2Packing leakagePacking gland looseTighten the packing gland
Insufficient fillingAdd filler
Filler technical performance does not meetReplacement of packing
The valve stem is rough, bent, and has axial groovesImprove surface finish, straighten valve stems, and repair grooves
3Middle flange leakageUneven tightening of flange boltsConsistent bolt torque
The technical performance of the padding material does not meet the requirementsReplace the bedding
Flange sealing surface is defectiveRepair sealing surface
4Valve internal leakageForeign matter falls into the valve and sticks to the sealing surfaceRemove foreign matter
The spherical surface at the end of the valve stem is deformed or hangingRepair the sphere
Wear of the opening mechanism of the double-disc gate valveRepair the expansion mechanism
Sealing surface damageTraining
5No condensationThe valve on the steam pipeline before the valve is damaged or not openedIf the valve is damaged, it needs to be repaired. If the valve is not open, it should be opened.
The elbow of the steam pipeline before the valve is blockedClean the dirt in the pipeline, and the pipeline bending should meet the requirements
The filter is clogged with dirtClean the filter regularly
The trap is full of dirtRepair the filter and clean the dirt inside the valve
The control room is filled with air and non-condensable gas, so the valve cannot be opened.Open the valve cover to discharge non-condensable gas
The valve on the bypass pipe and the sewage pipe before the valve is leakingRepair or replace valve
6Exhaust steamThe valve cover is not tight, the pressure in the control chamber cannot be established, and the valve plate cannot be closed.Tighten the valve cover or replace the valve disc
The valve seat sealing surface and valve disc are wornRegrind, if it cannot be repaired, replace it
There are impurities between the valve chamber and the valve plateOpen the valve cover to remove debris
7Drainage continuesDrastic increase in water discharge in steam pipesThe boiler sometimes bubbles and sends out a large amount of water. A steam-water separator should be installed to solve this problem.
The selected steam trap displacement is too smallThe problem should be solved by replacing the steam trap with a large drainage capacity or connecting it in parallel.
workshop01
workshop4

Please fill in your email address to obtain the password to view VR permissions.

Captcha
9 + 4 = ?
Reload
True Efficiency Use VMV

What can we do for you?
 
1. 26 years of brand history and industry experience.
2. Complete certificates, first-class standard.
3. Stable and high level product quality.
4. Regular products, delivery within 7 days.
5. Price support, adapt to the local market.
6. Team of 37 engineers, reliable technical support.
7. Professional training, online and offline form.
8. VR live display, not limited by geography.
9. Sale and service, 12 hours quick response.
etc…

Talk with us
Captcha
8 - 3 = ?
Reload